CdSe: enthalpy of formation

10 accepted literature formation-enthalpy value(s) (unspecified 10).

Systems: Cd–Se

Literature values

Enthalpy of formation of CdSe reported in the literature (10)
ValuePhase as printedT (K)ClassMethodSystemSourceLocationQuote
-158 kJ/mol (basis unstated)CdSeunspecifiedCd–Se[1] Liu 2012Table IV, p. 6, row 4
report
-147.7 kJ/mol (basis unstated)CdSeunspecifiedCd–Se[1] Liu 2012Table IV, p. 6, row 12
report
-147.03 kJ/mol (basis unstated)CdSeunspecifiedCd–Se[1] Liu 2012Table IV, p. 6, row 20
report
-144.1 kJ/mol (basis unstated)CdSeunspecifiedCd–Se[1] Liu 2012Table IV, p. 6, row 10
report
-142.6 kJ/mol (basis unstated)CdSeunspecifiedCd–Se[1] Liu 2012Table IV, p. 6, row 14
report
-141.96 kJ/mol (basis unstated)CdSeunspecifiedCd–Se[1] Liu 2012Table IV, p. 6, row 18
report
-139.4 kJ/mol (basis unstated)CdSeunspecifiedCd–Se[1] Liu 2012Table IV, p. 6, row 2
report
-139 kJ/mol (basis unstated)CdSeunspecifiedCd–Se[1] Liu 2012Table IV, p. 6, row 6
report
-136.6 kJ/mol (basis unstated)CdSeunspecifiedCd–Se[1] Liu 2012Table IV, p. 6, row 8
report
-136.5 kJ/mol (basis unstated)CdSeunspecifiedCd–Se[1] Liu 2012Table IV, p. 6, row 16
report

Uncertainty budget

Components kept separate, in the value's unit (literature SCHEMA.md, UNCERTAINTY_CALIBRATION.md): effective = max(sqrt(max(printed, reading, method)^2 + composition^2 + conversion^2), scatter). The method floor is the robust between-study scatter of the method class in ORCHID (calibrated) or a documented prior; printed values and printed uncertainties are unchanged.

Uncertainty budget of the literature values of CdSe
ValueUnitPrintedReadingMethod (class, basis)CompositionScatterConversionEffective
-158kJ/mol (basis unstated)0.057 (unknown, calibrated)7
-147.7kJ/mol (basis unstated)0.057 (unknown, calibrated)7
-147.03kJ/mol (basis unstated)0.0057 (unknown, calibrated)7
-144.1kJ/mol (basis unstated)0.057 (unknown, calibrated)7
-142.6kJ/mol (basis unstated)0.057 (unknown, calibrated)7
-141.96kJ/mol (basis unstated)0.0057 (unknown, calibrated)7
-139.4kJ/mol (basis unstated)0.057 (unknown, calibrated)7
-139kJ/mol (basis unstated)0.057 (unknown, calibrated)7
-136.6kJ/mol (basis unstated)0.057 (unknown, calibrated)7
-136.5kJ/mol (basis unstated)0.057 (unknown, calibrated)7

Sources

  1. Yajun Liu, Zhitao Kang, Guang Sheng, Lijun Zhang, Jiang Wang, Zhaohui Long, Phase Equilibria and Thermodynamic Basis for the Cd-Se and Pb-Se Binary Systems, Journal of Elec Materi 41, 1915-1923 (2012). doi:10.1007/s11664-012-2016-7