Components kept separate, in the value's unit (literature SCHEMA.md, UNCERTAINTY_CALIBRATION.md): effective = max(sqrt(max(printed, reading, method)^2 + composition^2 + conversion^2), scatter). The method floor is the robust between-study scatter of the method class in ORCHID (calibrated) or a documented prior; printed values and printed uncertainties are unchanged.
Uncertainty budget of the literature values of PdSe2
Value
Unit
Printed
Reading
Method (class, basis)
Composition
Scatter
Conversion
Effective
-86.4
kJ/mol (basis unstated)
1.8
0.05
10.5 (unknown, calibrated)
10.5
-86.67
kJ/mol (basis unstated)
0.005
11.7 (model_calculated, calibrated)
11.7
-86.4
kJ/mol (basis unstated)
1.8
0.05
11.7 (model_calculated, calibrated)
11.7
Sources
S. Bordier, A. Chocard, S. Gossé, Thermodynamic assessment of the palladium–selenium (Pd–Se) system, Journal of Nuclear Materials 451, 120-129 (2014). doi:10.1016/j.jnucmat.2014.03.044